Search by Tags

WEC iMX6 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the iMX Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

V1.0beta4 (Release date: 2015-08-27)
- WEC 7 Updates: Installed Microsoft CE7 Updates June 2015
- WEC 2013 Updates: May 2015
Added preliminary support in Toradex Libraries for I2C
WC-532FixedSetting a custom baud rate above 115200bps does not work using .NET Compact FrameworkApalis iMX6, Colibri iMX6UARTWEC7, WEC2013

Description: .NET Compact Framework checks if the required baud rate is in the range supported by the serial port before setting it. BSP reports the maximum standard baud rate (115200baud) as its maximum supported value, and this leads to an exception when an application tries to set baud rate. This issue has been fixed in version 1.0 beta 4