Issue #StatusSubjectModuleSubsystemWinCE OS

Not Planned
WC-466Known IssueTCP DHCP settings "Lease Expires" date is wrongApalis iMX6, Colibri iMX6EthernetWEC7

Description: The "Lease Expires" date is always set to 1/1/1970 initially. This seems to be WEC7 related issue. This is not an issue on CE6.

Workaround: Do a ip renew (ipconfig /release, ipconfig /renew) to get a correct "Lease Expires" date. If you build your own Image, you can also use a legacy dhcp.dll. Get a dhcp.dll which was build with an MS update level before November 2014, there this was not an issue.