Search by Tags

WEC iMX6 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the iMX Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

V1.1beta4 (Release date: 2016-11-25)
- WEC 7 Updates: Installed Microsoft CE7 Updates until September 2016
- WEC 2013 Updates: Installed Microsoft CE8 Updates until September 2016
WC-467FixedNetwork connection speed and duplex can be configured in registryApalis iMX6EthernetWEC7, WEC2013

Description: Customers reported that Apalis modules don't connect to some 1000Mbps hubs and routers.

Workaround: In version 1.1beta2 some parameters can be used to force the speed and mode of the ethernet controller, bypassing auto-negotiation. The parameters must be saved under HKEY_LOCAL_MACHINE\Comm\ENET1 - SpeedMode (can be 10,100 or 1000) forces connection speed - DuplexMode (can be 0 for half duplex or 1 for full duplex) forces connection mode