Search by Tags

WEC iMX6 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the iMX Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

1.2b4 (Release date: 2017-05-12)
- WEC 7 Updates: Installed Microsoft CE7 Updates until January 2017
- WEC 2013 Updates: Installed Microsoft CE8 Updates until March 2017
WC-255FixedUART baud rate is not using full precisionApalis iMX6, Colibri iMX6UARTWEC7, WEC2013

Description: For some baud rates the actual bit rate is not very precise and this may lead to problems with devices that are not able to auto-adjust their baud rate, mostly when a large amount of data is transferred with no interruptions.

Workaround: Issue has been fixed in release 1.2b4