Search by Tags

WEC T20 / T30 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the Tegra Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version (e.g. V1.3beta1) will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

View All Submitted (open) Released (closed)
Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

V1.3 (Release date: 2014-12-12)
- WinCE 6 Updates: Installed Microsoft CE6 Updates until 2014M07
- WEC 7 Updates: Installed Microsoft CE7 Updates until 2014M08
Release 1.3 contains all changes from 1.3 beta 1 to 1.3 beta 3.
WC-1864FixedSystem Hang on power supply drop below 3.08VColibri T20Bootloader, KernelCE6, WEC7

Description: The system was hanging when power supply dropped below 3.08V but did not go below 2.0V.

Workaround: A full power cycle is necessary to get the module out of this state. In Image 1.3beta1 and later we have implemented a software option to either trigger a reset as soon as the voltage drops below 3.08V, or ignore that low-voltage condition at all. See http://developer.toradex.com/wiki-articles/resource-manager-registry-settings#Undervoltage_Lockout for more details. Both options are not effective during the system boot phase, from the time when the power supply rises above 3.2V, until the power management IC has been configured by the WinCE driver.