Search by Tags

WEC VF50 / VF61 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the Vybrid Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

V1.0beta6 (Release date: 2014-06-06)
WC-2496FixedSystem tick is not configured at 1msColibri VF50, Colibri VF61KernelCE6, WEC7, WEC2013

Description: The system tick was configured using 50MHz as value for the clock speed used by the timers. The real value is 66MHz for VF50 and 83MHz for VF61. This error impacts the actual lenght of Sleep calls and all the timeouts used for wait functions.

Workaround: The issue has been fixed and tested. The fix will be released in the next update.