1.5b4 (Release date: 2017-10-19)
- WinCE 6 Updates: Installed Microsoft CE6 Updates until June 2017
- WEC 7 Updates: Installed Microsoft WEC7 Updates until June 2017
- WEC 2013 Updates: Installed Microsoft WEC2013 Updates until August 2017
WC-2449FixedNTP crashes all services at bootColibri VF50, Colibri VF61EthernetCE6, WEC7, WEC2013

Description: When the device is configured to use a static IP and a DNS is also configured sometimes the NTP client (time synchronization) crashes at boot, and this may impact other networking services. This issue was introduces with the Microsoft March 2017 updates.

Workaround: If you don't need NTP client you can disable it by changing the registry configuration.