Search by Tags

WEC VF50 / VF61 BSP Release

 

The following table contains known issues, scheduled bug fixes, and feature improvements for the Vybrid Windows CE BSPs and images.

Any schedules are not guaranteed, but reflect the current planning. The planning could be shifted due to priority changes.
Issues which are scheduled for a specific version will be integrated in the mentioned version of the BSP.

We will update this table continuously in order to always provide the latest state of our development plan.

Odd beta versions, as 1.0b1 or 1.3b3, are internal releases only for testing. They are omitted from the table.

Clear Filter
Issue #StatusSubjectModuleSubsystemWinCE OS

V1.2beta1 (Release date: 2015-07-22)
- WinCE 6 Updates: Installed Microsoft CE6 Updates until May 2015
- WEC 7 Updates: Installed Microsoft CE7 Updates until May 2015
- WEC 2013 Updates: Installed Microsoft CE8 Updates until May 2015
WC-2526FixedFixed buffer overflow on serial portColibri VF50, Colibri VF61UARTCE6, WEC7, WEC2013

Description: Fixed issue that would create buffer overflow inside UART driver. It's still possible to get an overflow when using big packages or high data rates without using flow control!

Workaround: Please use RTS and CTS flow control if you have bigger data packages or high data bandwidth.