Shock and Vibration Compliance Tests
Introductionā
Shock and vibration tests compliance is an important measure for many industries. Many people are worried about these tests when it comes to modules. However, it isn't a problem for our modules and the module approach in general to comply with many different standards.
The vibration tests were conducted on a shaker fixture plate setup and pictures of the setup are provided in the test reports. While the devices under test were exposed to vibration and shock, software was executed to detect discontinuities in the edge connector or failures on the module and carrier board. The vibration and shock tests have been performed on fifteen different combinations of Toradex carrier boards and Computer on Modules. Proper fastening methods were applied: screws, heatsinks, fasteners or SODIMM fingers.
Hardware Configurationā
Computer on Module | Carrier Board | Fastening Method |
---|---|---|
Apalis iMX6D 1GB IT | Ixora | Screws |
Apalis iMX6Q 1GB | Ixora | Apalis Heatsink |
Apalis iMX8QM 4GB WB | Ixora | Screws |
Apalis TK1 2GB | Ixora | Apalis Heatsink |
Colibri iMX6DL 512MB IT | Iris | No fastening (SODIMM fingers only) |
Colibri iMX6DL 512MB IT | Iris | Colibri Fastener |
Colibri iMX6ULL 512MB WB IT | Viola Plus | Screws |
Colibri iMX7D 512MB | Viola Plus | Screws |
Colibri T30 1GB IT | Iris | Colibri Fastener |
Colibri T30 1GB IT | Viola Plus | Screws |
Tests and Resultsā
This section provides a list of tests executed as well as the full test reports, which contain comprehensive specification, procedures and result information. The test procedures have been performed by a leading independent and internationally accredited testing laboratory company (ISO/IEC 17025), inspection body (ISO/IEC 17020), Quinel AG.
Broad-band Random Vibrationā
Result: passed for all configuration
- Standards: EN 60068-2-64:2008
- Frequency range: 10Hz-2kHz
- RMS level: 57.9m/s2
- Duration of exposure: 32h / axis
- Testing axes: in all 3 main axes
- Report: U2243-21a-18